In a raid 5 array configuration, the user data and parity data encoded redundant information are distributed across all the drives in the. Their systems database is growing in size at a really fast pace, and soon ill have to replace the drives. Hp smart array p420i raid 5 hdd and volume expansion. It shows same on rom bois and with hp array configuration utility. Buy hp proliant dl380p gen8 2u rackmount 64bit server with 2x8core e52667v2 xeon 3. P420i is soldered on the motherboard, p420 is a pcie card, otherwise no difference. Go into ssa, add the spindles to the array so the array has free space to do the migration. The hp ssd smart path feature included in the smart array software. I have an hp dl360 g8 with a smart array p420i with 3 physical drives, currently setup raid 0, i would like to migrate to raid 5. Configuring arrays on hp smart array controllers reference. Is it possible to convert raid 1 to raid 5 without loosing data,os, and partition on raid 1 drives while converting to raid 5. The hpe smart array e208ia sr gen10 controller, supporting 12 gbs sas and pcie 3. Hp smart array p420i controller raid1 configuration youtube.
Install is an hp smart array p420i bbwc enabled sas array a not in question this array has the system volume and an additional data volume. You can mix and match raid levels on smart array controllers. Hi all, were doing a ceph build and are using some rather old hp dl360p gen 8 servers which have integrated p420i raid controllers with 1gb caches and bbus. Hp server with p420i migrate to raid 5 error server fault. On the spec sheet of p420i hp raid controller, it says the maximum number of logical drives is 64 with 512 mb cache or above. Smart array p410i on dl 380 g6 shows only raid 1 and raid. Up until windows 8, software raid in windows was a mess. When the expansion finished, it shows that i have unused space in the array but it still wont show me the option to extend the logical drive.
Im trying to install a fresh install of server 2012 r2 on a hp server dl380gen8. The hp smart array family brings an unparalleled return on investment. But what is the limit of the number of arrays one can create. Then i disabled pxe option rom for that pcie slot in the supermicro bios and added a drive to be used as the os drive installed the os and using the raid array as a secondarydatavm partition. Raid controllers free delivery possible on eligible purchases. Configuring hp smart array p420i io controller for vsan. This software consistency of tools reduces the cost of training for each successive generation of. Were going to be filling these servers with intel ssds most likely s4510 960gbs, but from googling im a little concerned. When a hardware raid controller is available, ontap select can move. P420i ssa online raid migration 4 disk raid 5 array on a p420i 1gb controller. Hp smart array fbwc capacitor battery for p222, p420, p420i. See attached logically, the server has 2 raid 5 containers. Some software requires a valid warranty, current hewlett packard. The array hosts the os and 4 vms sbs 2011, terminal server 2008, powerchute apc appliance and a vcenter appliance.
Is a hp dl360p gen8, so we needed to reinstall the esxi 5. Unable to load controller drivers for smart array p420i. Hp proliant dl560 g8 5 bay sff 2u server, 4x xeon e54620 2. The process for array transformation is described in the array configuration utility manual under the migrating raid level or stripe size section. Windows 7 has arbitrary restrictions on the available raid levels, and it was impossible to create a level 5 raid without windows server. Selecting the best hpe smart array controller for your server. Hp smart array p420i raid 5 hdd and volume expansion you have a couple of options, you can easily add two more 1tb drives and expand the current raid 5. Hp proliant dl380p gen8 2u rackmount 64bit server with 2. Power supplies, no os with fast shipping and toprated customer service. In the smart storage admin cli if i issue ctrl slot0 ld 1 modify raid 5. The most important thing is to back up data on raid 5.
Hp proliant dl380p gen8 2u rackmount 64bit server with. We had the ram bumped up to 128gb and then suggested changing the existing 4 disk raid 10 plus hot spare into a raid 6 array across 8 disks. I have same server and i created raid 5 but on this server i didnt get option to choose raid 0. The hpe smart array p420i controller is a low profile, 6 gbs, pcie 3. Im booting the server and press f5 when it shows the info about smart array controller. Hpe smart array p420 controller hpe smart array p420i controller the hpe smart array p420 controller is a low profile, 6 gbs, pcie 3. Windows vista, windows 2003, windows 2000, windows xp. If you want to replace the existing array with larger drives, you will need to replace each disk one at a time waiting for the array to recover between each disk swap. These esxi host have 4tb of local storage, so we need to reinstall the esxi without destroy the local vmfs storage. Create a raid logical volume that uses all physical disks on a server. It only supports raid 0 mode, thus, its the only option. Configuring arrays on hp smart array controllers reference guide.
Yes, it did, in fact telling me that best practice for raid5 includes a maximum of 14 disks, i think. Hp proliant ml350p gen8 disk raid array performance running. Works fine and performance is great, and overall, its actually better to have standalone os drives from your raid arrays. Hp smart array p420i controller storage controller raid. Both are proper classic smart array controllers rather than the dynamic smart array controllers which are a bios mod to the chipset fakeraid controller.
Fortunately, it is easy to build a software raid 5 in windows 8. How to use hp command line array configuration utility. Raid 10 adm, raid 5, raid 50, raid 6, raid 60 power. Data sheet fujitsu praid ep400i ep420i raid controller sas 12gbits 1gb or 2gb cache based on lsi megaraid for internal storage devices main features benefits 12gbits sas ports pci express 3. Hp smart array p420i controller raid1 configuration. Hp proliant dl380p gen8 2u rackmount 64bit server with 2x8. Hp smart array fbwc capacitor battery for p222, p420.
Outfitting the hpe dl380 g6 with 3 graphics cards 583 duration. Overview of the raid 5 rebuild process in a redundant array of independent disks raid configuration, data are stored in arrays of drives to provide fault tolerance and improved data access performance. Yes, ideally youd use a passthrough mode controller but he p420i works well, has high queue depth, and supports a large number of drives so its a good choice for vsan. Vmware recommends that you use raid5 for sas drives and raid6 for sata drives. Then, follow the steps below to add extra raid 5 drive. No raid 5 option in offline acu interface we have proliant dl380p gen8 with smart array p420i controller. Im seeing conflicting advice on whether or not i can stick consumer sata disks ssd or hdd into the existing trays and have the server recognize the drives, allow me to use them, and not lose its mind. Verified both on post f8 for the controller and using smart start. We just need a couple of disks, and we will have the extra security. This has worked great for me in the past with fewer disks, though.
If raid 5 is running out of disk space, you can add a new disk to extend the raid 5. Hp smart array p420i controller storage controller raid sata 6gbs sas 6gbs pcie 3. Now based on how its always worked, and hps own documentation how you would do an online migration to raid 10 is add some spindles. Comparing 4 kib random write performance with 512 mib versus 2 gib fbwc. Smart array controllers and smart host bus adapters hpe. Physically, sas array b has 6 300gb sas drives installed. The hp proliant dl380p gen8 sets the next generation standards of 2u 2socket rack servers for the industry. Hello, i have at one of my customers a hp proliant ml310e gen 8 with a hp smart array p420i 2gb cache configured with raid 5, 3 x 1tb hard drives. The raid level used for the logical drive depends on the number of physical drives one drive raid 0. Hp dl360p gen8 p420i controller ixsystems community. First, download the new firmware version from the official site support. Hp p420ip440i hba mode on if you want to use embedded controller on dl series without the smart raid and just as passthroughhba itmodejbod controller raz1 jun 3, 2015 5.
Hewlett packard enterprise hpe smart array p420i raid. Many servers come with controllers that use software raid and these are often. If the drives have different capacities, orca locates the smallest drive and uses the capacity of that drive to determine. Key raid data protection feature raid levels 0, 1, 5 and 6 raid spans 10, 50 and 60 maximum number of spans is 8 online capacity expansion oce online raid level migration rlm auto resume after loss of system power during array rebuild or reconstruction rlm fast initialization. Family data sheet hp proliant gen8 smart array controllers.
This allocates one set of parity data across drives and allows. Jun 27, 2014 the p420i does not support passthrough mode. I have a hp proliant ml350p gen8 server running esxi 6. I have a new dl580 g7 with p410i controller and 8 146g 15k sas drives. When using the smart storage gui when i attempt to migrate the drive i am only offered raid 0 and the option of changing stripe size. Buy hp smart array p4201gb fbwc 6gb 2ports int sas controller smart array p420 raid sas pcie3.
Smart array controllers, and hp proliant storageworks raid array controllers. If a customer has an hp smart array p222, p420i, p420, p421, or p721m controller with an hp saap 2. Retired products sold prior to the november 1, 2015. May 30, 2017 up until windows 8, software raid in windows was a mess. Adding 4 new disks to a raid 10 array we started off with a new hp ml350p g8 that our now client had purchased.
Hp proliant dl380p gen8 2u rackmount 64bit server with 2x8core e52667v2 xeon 3. Feb 14, 2016 detailed step by step raid 5 configuration of smart array p440ar controller on hp dl380 g9 server, step by step video tutorial available from the live server. Also, professional raid backup software can help you back up data if you find it difficult to back up data manually. Feb 24, 2017 i have a dl380 gen8 in my homelab with a p420i raid controller minus the cache module. Hp smart array p430 and p420 controllersadvanced raid functionality for. Each raid 5 parity group can sustain a single drive failure without. Guibased configuration, management, and diagnostic software toolsfacilitate.
565 758 849 520 692 1401 619 452 20 354 293 511 404 654 985 1339 638 694 977 1447 858 250 1155 1183 622 518 984 626 13 153 613 1024 827 1313